Press the left button, drag the mouse, rotate the cube, see more information

Limit Discounts

Through this webpage, choose online customer service communication, or message board. Leave your needs and get limited time discounts, up to 10% off, saving you a fortune. This discount has an indefinite period, and places are limited on a first-come, first-served basis.

Payment Method

We support various payment methods:
T/T payment
VISA
paypal
MasterCard
Alipay etc
Save time in your buying process.

Certified Product

The company's products have passed multiple national
certifications:
for example:
United States: ASME
EU: CE
Eastern Europe: EAC
Russia: GOST
Singapore: MOMO
etc
Buy products, buy with confidence, use with confidence

Product Type

Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler

About Us

FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!

Contact Us

If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.

Primary Secondary Piping and Water Tube Boiler Cycling

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :Primary Secondary Piping and Water Tube Boiler Cycling
  • Supply Capacity : 10 units/month :Primary Secondary Piping and Water Tube Boiler Cycling
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • I. PIPING DIAGRAMS - Water and Space Heating

    2. Boiler circulator(s) must be rated for open loop applications. Do not use cast-iron circulators. 3. Boiler circulator(s) operate continuously. 4. The minimum pipe size for connecting to a water storage tank is 1 ½". 5. The minimum pipe size for connecting the boiler is 1 ½" for the Mod Con 300 VWH and 2" for the 500 and 850 models. 6.Get Price

  • Hydronic Pipe Layout | Terry Love Plumbing Advice

    Jan 21, 2022 · Above 130° 86%. Boiler side should be piped with primary/ secondary loop with back to back tees or the Navien manifold system. problems with your piping like to see spring check valves on the pumps keep water flowing backwards thru pumps that are off. Is the fin tube 1/2" or 3 /4" piping looks 1 /2" .Get Price

  • RIDE THE LOCHINVAR WAVE

    (variable primary) system. Installation is streamlined, without the time and materials cost of primary/secondary piping, and pumps needed to maintain flow in a water-tube boiler. Variable flow also makes CREST more flexible at handling frequent fluctuations in the system flow rate.Get Price

  • Hydronics piping checks can be a breeze - Contractor

    Mar 01, 2006 · Sizing the circulator for the recommended flow is a must. Even with primary/secondary piping, non-condensing boilers may require boiler protection. Contrary to some beliefs, primary/secondary alone does not offer full boiler protection. Manifold piping and boiler primary loops normally require a minimum of bypass piping for boiler protection.Get Price

  • Right-Sizing Your Boiler Plant Will Optimize System

    Aug 29, 2019 · • If an existing system utilizes primary-secondary piping and building demand is upward of 1MMBH, converting to a primary-only arrangement will lower operating costs. It must be noted that water tube heat exchangers should only be installed in a primary-secondary system to protect the heat exchanger from ∆Ts greater than their design allows.Get Price

  • Avoid combi-boiler short cycling with piping configuration

    Oct 08, 2019 · Reading through this forums and research on the internet however suggests that this would cause short cycling on the space heating side due to the heat load of individual heating zone is a lot lower than the combi boiler minimum btu. One contractor argues that short cycling can be avoided by using primary/secondary piping (or pumping Get Price

  • Tips For A Successful Cast Iron Water Boiler Installation

    Jul 16, 2018 · Primary/secondary piping option. Primary/secondary piping utilizes hydraulic separation so that the water flow from system pumps do not affect boiler pump flow. This allows us to reduce the flow through the boiler to heat the water faster and heat the water to a higher temperature without affecting the flow in the system.Get Price

  • Primary/Secondary Manifold

    Primary/Secondary Manifold ˝ water leaking from the manifold or connections will not cause damage to the area surrounding the Primary Boiler Supply Drain Valve Fig. 1: Typical Piping Configuration. Primary/Secondary Manifold 2 D D SR1 D SR1 SS1 SS1 SR2 SR2 SS2 SR1 SR1 SS1 SS1 SS2 SR2 SR2 SS2 SS2 SR3 SS3 SR3 SS3 SR3 SS3 AV AV PS PR AV Get Price

  • RIDE THE LOCHINVAR WAVE

    (variable primary) system. Installation is streamlined, without the time and materials cost of primary/secondary piping, and pumps needed to maintain flow in a water-tube boiler. Variable flow also makes CREST more flexible at handling frequent fluctuations in the system flow rate.Get Price

  • Free to Move - Flexible Water Tube Boilers from Bryan

    controls used in the construction of the boiler can be purchased locally for fast repair. Variable Primary or Primary/Secondary Piping Not only are our tubes flexible, but so are the different ways to pipe Free-Flex. With low water pressure drops, the Free-Flex is able to operate in low flowGet Price

  • Primary - Secondary Piping and Water Tube Boiler Cycling

    Understanding primary-secondary pumpingGet Price

  • Hot Water Boilers and Controls - Ashrae Bi-State

    Generally use primary-secondary scheme Primary pump is supplied on the boiler Primary pump sized to match the boiler requirements Too much flow can cause erosion of boiler tubes Too little flow can cause local overheating Boiler mounted pumps run with the boiler Shut down when boiler is off line Secondary pumps run via BMS controlGet Price

  • Hydronic Condensing Boiler Heating Buffer Tanks - Part 1

    boiler primary pump's flow rate far exceed the system flow rate at minimum load. Boiler loop flow overwhelms the secondary loop flow in the common piping between the two primary-secondary connections. This rapidly raises the boiler's entering water temperature and can trip the boiler's high temperature operating limit on low load.Get Price

  • Beyond Primary / Secondary Piping - Caleffi

    Primary - Secondary Piping and Water Tube Boiler Cycling Mo n da y Mo r n in g Min u te s | by No r m Ha ll, No v e mbe r 2, 2020 Primary - Secondary piping is recommended with most water tube condensing boilers. Once the boilers have turned down to the lowest firing rate, cycling will occur. Today the R. L. Deppmann Monday MorningGet Price

  • Zoned hydronic distribution system | Kefid | Plumbing

    Dec 09, 2014 · December 2014 Glitch drawing: An installer sets up a zoned distribution system as shown above. To keep it simple, he uses the same size piping for the headers and all the distribution circuits. The heat source is a low-mass copper tube boiler with high flow resistance.Get Price

  • What is Short-Cycling and How Can You Prevent it?

    Short cyclin g occurs when a boiler powers down before being able to complete a typical boiler cycle and is called upon to satisfy a second call for heat, in quick succession. A typical boiler cycle consists of firing, post purge, idle period, pre-purge and then back to firing. Boiler short cycling can be seen in two critical areas; mechanical and economic.Get Price

  • Modern HydronicSystem Designs for Condensing Boilers

    Primary/Secondary Arrangements The Basics • Decouples or "hydraulically separates" the primary (boiler) and secondary (system) loops –Closely spaced tees or a mixing manifold • Prevents flow in one circuit from interfering with another –Example: As zone valves open, close, or modulate, and as system pumps vary speed, the boiler loop isGet Price

  • Primary Secondary Piping | RL Deppmann

    Nov 09, 2020 · When supplied with four system connections, as shown above, it serves as the low velocity primary secondary common pipe. The boiler fires and charges the tank with hot water. The tank stratifies and the boiler shuts down. The load is …Get Price

  • HIGH EFFICIENCY BOILERS - Ferguson

    This permits installation of a "full flow" (variable primary) system eliminating the time and materials cost of primary/secondary piping, and pumps needed to maintain flow in a water-tube boiler. Variable flow also makes FTXL more flexible at handling frequent fluctuations in the system flow rate.Get Price

  • Five Design Factors To Help Optimize A Boiler Plant

    both primary and secondary loops had fixed speed pumps. Through the years, variable speed pumps were Another factor is if the boiler is fire- or water-tube. them ideal for variable-primary piping. Conversely, water-tube boilers tend to have higher pressure drop and minimum flow requirements, so primary-second-ary piping is typically used.Get Price

  • Primary/secondary plumbing for condensing boiler - YouTube

    Jul 02, 2012 · Actual picture and explanation of proper way for primary secondary boiler piping, Like these videos? just type in loudepot in any APP store, and for .99 cenGet Price

  • Condensing Boiler Plant Piping - James M. Pleasants Company

    Feb 10, 2015 · Mar 23, 2015. Condensing Boiler Plant Piping Design & Control Part 6: Boiler Cycling and Supply Delta T. Mar 23, 2015. Identifying the stop and start range of a boiler system is a critical first step in controlling boiler staging and/or sequencing. This range defines what the boiler supply temperature is at full fire and what the supply Get Price

  • Hydronic Boiler Comparison: Fire-tube Boilers vs. Water

    Aug 12, 2020 · A water-tube can be a great selection on a retrofit job with limited space for a large boiler. A primary secondary set up is very easy to integrate with an existing system. A fire-tube can also be the better solution if you are designing a …Get Price

  • Design Tips to Avoid Boiler Short-Cycling - P2S Inc

    Nov 02, 2020 · Primary – Secondary Piping and Water Tube Boiler Cycling Norm Hall November 2, 2020 Boilers, Condensing, Hydronic Design, Monday Morning …Get Price

  • HIGH EFFICIENCY CONDENSING BOILERS - Lochinvar, LLC

    Aug 12, 2019 · Primary Secondary (P-S) hydronic piping is a common piping scheme in today's hydronic heating and cooling systems. This short series of blogs will provide examples of piping schemes which will support the reduction of hot water return temperatures to enhance the value of condensing boilers.Get Price

  • B&W Learning Center Articles - Babcock & Wilcox

    Cycling Boiler Circulation Upgrade The solution in most cases is to modify the boiler and/or feedwater system to prevent the sudden entry of cold water into hot boiler components. This velocity serves to prevent the coal particles from dropping out of suspension in horizontal runs of coal pipe. Minimum primary air flow is the greater of Get Price

  • Modulating Condensing Boilers - Madison Gas and Electric

    As noted, primary secondary piping was used to support 140ºF return water to the boiler. Adding a condensing boiler to an existing primary secondary loop can be done. However, it is now common practice to add a designated hydraulic separator to help minimize short-cycling.Get Price

  • The Eolution of Primary/ Secondary Pumping - ASHRAE

    water—a primary loop that exits from and returns to the boiler and a secondary loop that takes water from the primary loop and moves it around a room or simi-lar "zone." This arrangement needs two or more cir-culator pumps, but these can be small, energy-saving pumps. In primary/secondary applications, the primary andGet Price

  • Primary/Secondary Manifold

    Primary/Secondary Manifold ˝ water leaking from the manifold or connections will not cause damage to the area surrounding the Primary Boiler Supply Drain Valve Fig. 1: Typical Piping Configuration. Primary/Secondary Manifold 2 D D SR1 D SR1 SS1 SS1 SR2 SR2 SS2 SR1 SR1 SS1 SS1 SS2 SR2 SR2 SS2 SS2 SR3 SS3 SR3 SS3 SR3 SS3 AV AV PS PR AV Get Price

  • Turndown Ratio in Condensing Water Tube vs. Fire Tube

    Oct 19, 2020 · Turndown Ratio in Condensing Water Tube vs. Fire Tube Boilers (Part 1 of 2) Turndown is defined as the ratio of maximum fuel input rate to the minimum fuel input rate of a variable input burner. In general, it refers to the ability to adjust a boiler's firing rate (input) to precisely meet the real-time heating demand (output) of the system Get Price