Press the left button, drag the mouse, rotate the cube, see more information

Limit Discounts

Through this webpage, choose online customer service communication, or message board. Leave your needs and get limited time discounts, up to 10% off, saving you a fortune. This discount has an indefinite period, and places are limited on a first-come, first-served basis.

Payment Method

We support various payment methods:
T/T payment
VISA
paypal
MasterCard
Alipay etc
Save time in your buying process.

Certified Product

The company's products have passed multiple national
certifications:
for example:
United States: ASME
EU: CE
Eastern Europe: EAC
Russia: GOST
Singapore: MOMO
etc
Buy products, buy with confidence, use with confidence

Product Type

Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler

About Us

FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!

Contact Us

If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.

Mechanism of Boiler And Steam Condensate Corrosion

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :Mechanism of Boiler And Steam Condensate Corrosion
  • Supply Capacity : 10 units/month :Mechanism of Boiler And Steam Condensate Corrosion
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • The Corrosion Problems in The Condensate Lines | Ayvaz

    Mar 22, 1998 · Condensate can be contaminated by release of corrosion products through metal dissolution or by separation of accumulated oxide layers from the metal surface during system startups or shutdowns. Corrosion products tend to deposit on boiler heat transfer surfaces (Figure 1)? reducing heat transfer efficiency and Musing boiler tube failures.Get Price

  • MANAGING CORROSION CHALLENGES ASSOCIATED WITH …

    Corrosion Challenges: Critical HE Hydrocarbon Service • Propane Condensers • Stripper Overhead Condenser Amine Service • Lean Solution Coolers Cooling Water Service • Cooling Water Heat Exchangers • Cooling Tower Steam/BFW Service • Sulfur Condensers • Boiler Feed Water Heat Exchangers • Condensate Reboilers • Regen Steam Get Price

  • Graphitic Corrosion of Cast Iron Steam Boilers

    Graphitic Corrosion of Cast Iron Steam Boilers Today's water is not the water of the 1950's, 1960's and 1970's By Paul Schuelke Director, Technical Services Weil-McLain. And effect of: EPA Lead and Copper Rule in 1991. Wisconsin Dept. of Natural Resources - 1988 Lakes in …Get Price

  • Condensate Corrosion in Steam Generating Systems | NACE

    Oct 22, 2017 · Na2 CO3 + H2O à 2 NaOH + CO2. This free carbon dioxide gas (CO2 ) is volatile and leaves the boiler with the steam and reacts with condensed water to form carbonic acid. CO2 + H2O à H2 CO3. Carbonic acid is a weak acid, but as the condensate water is pure, this weak acid reduces the pH significantly, often in the range of 5-6.Get Price

  • The International Association for the Properties of Water

    condensate or degassed demineralized water) into steam Caustic gouging CG A boiler/HRSG under-deposit corrosion (UDC) tube failure mechanism where NaOH concentrates beneath deposits Condensate Polishing Plant CPP System containing ion exchange resins to purify condensate. Can also include a filtration system Condensate Pump Discharge CPDGet Price

  • Steam Traps Explained: What Function Do They Perform in

    Jul 29, 2021 · Steam traps remove air and condensate to hold pure steam. Condensate is steam that has cooled below 212 degrees (condensed) and returned to the liquid state. It has to be funneled back into the boiler via a tank and reheated before it can be used for heat again. Removing condensate from the steam in your boiler system is essential.Get Price

  • Boiler Corrosion - an overview | ScienceDirect Topics

    Without treatment, such condensate attacks the return system, and brings back appreciable amounts of iron and copper oxides to the boilers: these can initiate boiler corrosion and interfere with water circulation in watertube boilers causing tube starvation. To counter these effects, volatile amines are used, and are of two types, neutralizing Get Price

  • thermax combloc boiler 2000kg

    thermax diesel fired boilers – Industrial Fire Tube Boiler. 2020/4/22 · THERMAX COMBLOC Multi Fuel fired Ultra Compact Steam Boiler 1500 Ask Price View More Thermax Gas Fired Boiler – IndiaMART Find here Thermax Gas Fired Boiler dealers, retailers, stores & distributors.Get Price

  • CORROSION PROTECTION OF CONDENSATE SYSTEMS

    Reaction #6 occurs by a differential aeration mechanism and results in pitting under corrosion products. When carbon dioxide is also present, the condensate low pH into the steam condensate lines. along with the boiler water scale & corrosion inhibitors, and continuous injection is required.Get Price

  • Workplace Exposures to Corrosion-Inhibiting Chemicals from

    Higher acute exposures through this mechanism are more likely if these chemicals are added to a steam-generating system in a single large quantity rather than continuously in small amounts. Most boilers require daily addition of fresh water to compensate for losses from escaping steam and drained condensate.Get Price

  • Corrosion Inhibitor for Steam Condensate Lines

    POA for 200kg/IBCs. Accepta 2329 is a high performance corrosion inhibitor scientifically formulated from a blend of neutralising and filming amines for the control of corrosion in steam and boiler condensate return lines. Because Accepta 2329 contains neutralising and filming amines it can protect the system from corrosion caused by both Get Price

  • The Effects of Corrosion in a Boiler | Chardon Labs

    Another cause of corrosion can happen when untreated condensate returns to the system, bringing dissolved iron and copper oxides with it back into the boiler. To prevent this type of corrosion, plants often use volatile amines in the form of either neutralizing or filming treatments, which prevent contaminants in condensate from producing damage.Get Price

  • Steam & Condensate Management Solutions - Spirax Sarco

    • Excessive corrosion of heating surfaces • Waterhammer • Noisy operation • Equipment damage Utilizing a Spirax Sarco condensate recovery system to effectively collect hot condensate from the steam and return it to the boiler house can pay for itself within a short period of time. condensate recovery solutionsGet Price

  • Condensate Water Treatment and Prevention of Corrosion in

    Jan 18, 2022 · It controls corrosion in condensate by eliminating the effects of carbon dioxide and other acid-forming compounds. Neutralizing amines are used for water treatment in a steam boiler to control condensate return line corrosion. The amines do not have any severe impact on copper or copper alloys under normal conditions, that includes pH between 7 Get Price

  • 7.0 Chemical Treatment - Steam Forum

    in the steam lines or in the boiler, to control carbonic acid and dissolved oxygen corrosion in the condensate lines. As a general rule, the higher the boiler pressure, the higher the quality of feedwater required. Therefore, the higher the pressure, the more chemical treatment is concentrated outside the boiler in water preparation (chapter 2 Get Price

  • CORROSION INHIBITORS – Boiler Systems (Amines & Oxygen

    The final phase of boiler system corrosion control occurs in the Condensate System. Because of carryover, iron and copper corrosion is not limited to the piping and equipment of the condensate system. Corrosion products and process chemicals can return to the boiler causing damaging boiler deposits, and deposits on steam-driven equipment.Get Price

  • TIP 0416-26 Best Practice for Recovery Boiler Inspection

    same damage mechanisms. Fireside corrosion loops are defined primarily by the temperature and chemical characteristics of the combustion gas and the steels that they come into contact with in different parts of the boiler. Steel in contact with treated feed-water and steam is …Get Price

  • How Boiler Corrosion Occurs and How to Deal With It

    Nov 19, 2020 · Corrosion can also happen in a boiler when the pH of the water is too high or too low. Caustic corrosive damage occurs when a concentrated caustic agent dissolves and creates high pH. Acidic corrosion develops when the boiler water pH is too low. Improperly managed cleaning chemicals can also lead to acidic corrosion.Get Price

  • US5368775A - Corrosion control composition and method for

    A corrosion control composition and method for boiler/condensate steam systems is provided. Corrosion is controlled by the addition to the feedwater of a relatively high molecular weight amine. The high molecular weight amine is formulated so that at the conditions of temperature and pressure in the boiler/condensate steam system, partial degradation into more volatile …Get Price

  • Reducing Corrosion and potential Boiler Failure with

    2. Corrosion mechanisms Reduced reliability due to corrosion attack is one of the main problems in boiler systems costing billions of dollars per year. 2.1. Pre-boiler corrosion – Metal transport to boiler from external equipments Pre-boiler corrosion will include corrosion in all steam – condensate network and also in boiler feed water Get Price

  • Corrosion and corrosion product transport monitoring in

    Dec 31, 1994 · @article{osti_80100, title = {Corrosion and corrosion product transport monitoring in boiler condensate systems}, author = {Chen, T Y and Godfrey, M R and Avallone, S C}, abstractNote = {One of the major causes of fouling in boilers is corrosion in the condensate system caused by the presence of oxygen and/or carbon dioxide, and other changes in water …Get Price

  • Electromagnetic Filtering of Magnetite from Steam Boiler

    Electromagnetic Filtering of Magnetite from Steam Boiler Condensate Layers in Relation to Boiler Corrosion." W.M.M. Huijbregts, A. Snel (1) The second mechanism is mechanical in nature as the Magnetite and the steel tube have significantly different coefficients of expansion. When the …Get Price

  • API 571 Damage Mechanisms Affecting - Corrosion Clinic

    3.5 Ammonium Bisulfide Corrosion (Alkaline Sour Water) 3.6 Ammonium Chloride and Amine Hydrochloride Corrosion 3.7 Aqueous Organic Acid Corrosion 3.8 Atmospheric Corrosion 3.9 Boiler Water and Steam Condensate Corrosion 3.10 Brine Corrosion 3.11 Brittle Fracture 3.12 Carbonate Stress Corrosion Cracking 3.13 Carburization 3.14 Caustic CorrosionGet Price

  • Steam Boiler Service - Dodman Limited

    (Analysis of failure permits an assessment of mechanisms causing erosion and corrosion). STEAM AND CONDENSATE PIPEWORK ANALYSIS. Steam boiler water treatment is rarely examined as a complete circuit, specifically in how chemistry changes throughout the system Steam quality can influence heat exchange process performance.Get Price

  • Advanced methods for controlling boiler tube corrosion and

    In Part 1 of this article, the authors covered techniques for minimizing corrosion and contaminant ingress from condensate return and feedwater to industrial steam generators.While some corrosion mechanisms can cause severe damage to condensate and feedwater piping, heat exchangers and other equipment, the release of corrosion products or the transport of other …Get Price

  • Advanced methods for controlling boiler tube corrosion and

    In Part 1 of this article, the authors covered techniques for minimizing corrosion and contaminant ingress from condensate return and feedwater to industrial steam generators.While some corrosion mechanisms can cause severe damage to condensate and feedwater piping, heat exchangers and other equipment, the release of corrosion products or the transport of other …Get Price

  • Caustic corrosion in boilers - Lenntech

    2. the boiler-water must contain caustic, 3. at least a trace of silica must be present in the boiler-water, and. 4. some mechanisms, such as a slight leak, must be present to allow the boiler water to concentrate on the stressed metal. Stem blanketing is a condition that occurs when a steam layer forms between the boiler water and the tube wall.Get Price

  • Aspects of Failure of Condenser tubes and - Steam Forum

    scale and silt. Condenser corrosion problems have increased in the past few years, in part, as a result of higher pollution in cooling water. Many of the corrosion problems in fossil fuel boilers, LP steam turbines and feedwater heaters have been traced to leaking condensers. Tube leaks allow the ingress of cooling water into the steam-water cycle.Get Price

  • Impact of Corrosion on Steam Boilers and Piping - Boilers

    When copper-laden condensate reaches a steam trap and is discharged, the lower pressure on the outlet side of the trap will cause part of the condensate to flash into steam; some of the dissolved copper ions may precipitate and accumulate as solid build-up around the valve seat, causing orifice blockage and lowered temperatures in the tracing line.Get Price

  • Water Treatment for the Pharmaceutical - ChemTreat, Inc.

    Feb 10, 2021 · Boiler condensate/feedwater system treatment is a key aspect of protecting steam generation equipment. Typically, most of the piping in these networks is of carbon steel construction. Treatment programs are normally geared to minimize two primary corrosion mechanisms: general corrosion and oxygen attack.Get Price

Discount
7X24 Online