Press the left button, drag the mouse, rotate the cube, see more information

Limit Discounts

Through this webpage, choose online customer service communication, or message board. Leave your needs and get limited time discounts, up to 10% off, saving you a fortune. This discount has an indefinite period, and places are limited on a first-come, first-served basis.

Payment Method

We support various payment methods:
T/T payment
VISA
paypal
MasterCard
Alipay etc
Save time in your buying process.

Certified Product

The company's products have passed multiple national
certifications:
for example:
United States: ASME
EU: CE
Eastern Europe: EAC
Russia: GOST
Singapore: MOMO
etc
Buy products, buy with confidence, use with confidence

Product Type

Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler

About Us

FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!

Contact Us

If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.

The Permissible Hardness Of Water For Low Pressure Boiler

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :The Permissible Hardness Of Water For Low Pressure Boiler
  • Supply Capacity : 10 units/month :The Permissible Hardness Of Water For Low Pressure Boiler
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • Low pressure boiler practice test Flashcards | Quizlet

    Start studying Low pressure boiler practice test. Learn vocabulary, terms, and more with flashcards, games, and other study tools. The _____ is the part of the boiler with water on one side and heat on the other. Maximum allowable working pressure. Cast iron. A _____ boiler does not use tubes.Get Price

  • IS 10496 (1983): Feed Water, Boiler Water and Condensate

    2.1 Water-Tube Boilers ( Drum Type) - The feed water, boiler water and condensate, for water-tube boilers shall cotiply with the requirements given in Table 1. NOTE -In case of recovery boilers operating at low boiler pressures of I.5 to 2.0Get Price

  • DRAFT BOILER/FEEDWATER GUIDELINES

    pitting can result with possible rupture of boiler condensate piping or boiler tubes. 3.3.4 Rusty water in the boiler gage glass is a sure sign of acid corrosion in the boiler feedwater/condesate system or in the boiler itself. 3.3.5 Make-up water is the major source of carbon dioxide. The first priority is to minimize the amount of make-up water.Get Price

  • Low water pressure for a new combi boiler - MyBuilder

    Low water pressure for a new combi boiler. I have just purchased a 3 bedroom end terrace property (built 1982)where an old boiler (Glow Worm Ultimate 40ff) needs replacing. I was hoping to have a new Combi Boiler (Vaillant or Worcester) installed, however having had a representative from one of the "big six" energy companies (not sure if I Get Price

  • pH Treatment - CleanBoiler.org

    Alkalinity is a measure of the bicarbonate (HCO3), carbonate (CO3) and hydroxyl (OH) ions in the water. pH and alkalinity ratings are NOT the same and are NOT proportional. pH is rated on the Scale and alkalinity is measured in parts per million (ppm). A typically recommended alkalinity rating is 140 – 700 ppm for boilers operating below 300 psi.Get Price

  • §763. Low-Pressure Boilers. - California Department of

    (2) A low-water safety cutout that will shut off the fuel to the burner when the water in the boiler reaches a predetermined level which shall not be below the lowest permissible level, and manual resetting of the low-water control or of the fuel valve or of the emergency control system shall be required to place the boiler back in operation after it has been shut down due to the operation …Get Price

  • Boiler Water Conductivity Measurement Fundamentals

    Feb 24, 2016 · For boiler water, the conductivity increases at the rate of approximately 2% (of the value at 25°C) for every 1°C increase in temperature. This can be written as: σ T = σ25 [1 + α (T – 25)] σT = Conductivity at temperature T (µS / cm) α = Temperature coefficient, per °C (Typically 0.02 / °C or 2%°C)Get Price

  • Water Treatment for Boilers and WSC Chemistry - Kremesti

    Water-tube boilers and auxiliary installations. Part 12. Requirements for boiler feedwater and boiler quality. VGB Guidelines for Boiler Feedwater, Boiler Water and Steam of Steam Generators with a Permissible Operating Pressure of > 68 Bar – VGB-R 450 LeGet Price

  • Boiler Water - an overview | ScienceDirect Topics

    Maintaining the pH of boiler water in the range of 9–11 decreases the rate of corrosion; 9.2 to 9.8 is ideal. In low-pressure steam or hot water heating systems, nitrite or chromate provides a protective film on metal surfaces. Filming amines provide a physical barrier to protect metal from corrosion. They are effective in the pH range of 5.5 Get Price

  • WATER - Miura Boiler

    Dec 02, 2019 · Operating a boiler with hard water reduces e€ciency and can lead to serious damage, or even failure, of the pressure vessel. Miura's Colormetry monitor samples treated water and tests for hardness down to >1mg/L. If hardness is detected, the Colormetry will signal an alarm and increase surface blowdown to reduce damage to theGet Price

  • Managing downstream hardness upset in boiler systems

    Dec 20, 2018 · Justin Treece, U.S. Water Area Manager, and Ray Gesling, B.S.M.E. describe a recent case study in which a water technologist and pharmaceutical plant engineer teamed up to master and manage downstream hardness upset in a boiler system. One of the most prominent issues experienced with boilers is the formation of calcium carbonate scale on Get Price

  • Boiler Water - an overview | ScienceDirect Topics

    Maintaining the pH of boiler water in the range of 9–11 decreases the rate of corrosion; 9.2 to 9.8 is ideal. In low-pressure steam or hot water heating systems, nitrite or chromate provides a protective film on metal surfaces. Filming amines provide a physical barrier to protect metal from corrosion. They are effective in the pH range of 5.5 Get Price

  • 1 Water Technology - BS Publications

    Further knowledge of hardness of water helps in proper designing of engineering processes and structures. Two methods are popular in the estimation of hardness. 1. Soap titration method: This is a simple but somewhat qualitative method. In a simple test, usually performed for water to be used in a low pressure boiler, 70 ml of water isGet Price

  • (PDF) BASIC WATER TREATMENT OF STEAM BOILERS - …

    ASME Guidelines for Water Tube Boilers Drum Pressure Iron Copper Total Silica Total Conductivity (psig) Hardness Alkalinity 0-300 0.100 0.050 0.300 150 *700 7000 301-450 0.050 0.025 0.300 90 *600 6000 451-600 0.03 0.020 0.200 40 *500 5000 * Total Alkalinity must not be allowed to exceed 10% of the Conductivity.Get Price

  • Basics of the water chemical mode of low-pressure steam

    Ivan Tikhonov. In the article, as simply as possible (as it seems to the author), the basics of the water-chemical mode of low-pressure fire-tube steam boilers are presented. The water-chemical mode (WCM) of a steam boiler is an operating complex of technological solutions aimed at ensuring trouble-free and efficient operation of a steam boiler.Get Price

  • Water Treatment for Boilers and WSC Chemistry - Kremesti

    Water-tube boilers and auxiliary installations. Part 12. Requirements for boiler feedwater and boiler quality. VGB Guidelines for Boiler Feedwater, Boiler Water and Steam of Steam Generators with a Permissible Operating Pressure of > 68 Bar – VGB-R 450 LeGet Price

  • Boiler Safety and Role of Low Water Levels - Forbes Marshall

    Low-water level conditions in the boiler occur when the water in the boiler drum falls below the low water level mark. Such conditions have the potential to severely damage the boiler. The furnace temperatures usually exceed 1,800°F (980°C). The strength of steel drops sharply at temperatures above 800°F (480°C).Get Price

  • Boiler Water Treatment - Association of Water Technologies

    – When the feed water pump comes on, the boiling point of water is reduced – Deareators use head pressure (1 psi for every 2.3 feet of height above the pump), where a feed water tank is barely 3 feet above the feed water pumps. – Watch the temperature closely to prevent pump loss due to cavitation.Get Price

  • Basics of the water chemical mode of low-pressure steam

    Ivan Tikhonov. In the article, as simply as possible (as it seems to the author), the basics of the water-chemical mode of low-pressure fire-tube steam boilers are presented. The water-chemical mode (WCM) of a steam boiler is an operating complex of technological solutions aimed at ensuring trouble-free and efficient operation of a steam boiler.Get Price

  • Blowdown Tanks For Low Pressure Process Steam Boilers

    1. Electrically turn off boiler feed pump. 2. Blowdown low pressure steam boilers at or near operating pressure. 3. If boiler is equipped with fast & slow open-ing blowdown valves, open the fast one first, the slow one second. Shut blow-down valves off after water level in boiler gauge glass drops about 4" (see step 5). 4.Get Price

  • what is the hardness concentration of boiler water

    Hardness. The hardness of water is caused by calcium and magnesium ions which will vary greatly throughout the country depending on the source of the water. In boilers the hardness of the water can cause the formation of scale and sludge or mud. The hardness must be removed in the makeup water to the return system. Total hardness should not Get Price

  • Boiler feed water and boiler water treatment - Arveng

    Low pressure boilers do not require the same quality than high pressure boilers. In this way, the boiler feed water treatment required in such case, will differ considerably. A low pressure boiler can usually tolerate high feed water hardness with proper treatment while virtually all impurities must be removed from water used in high pressure Get Price

  • Is it dangerous if boiler pressure is too low?

    In respect to this, how do I increase water pressure in my boiler? If below 1 bar, your boiler has a low water pressure and needs re-pressurising. Locate the filling loop, often found on the underside of your boiler.Open both valves to allow water into your heating system. Keep an eye on the pressure gauge and close the valves when the pressure reaches 1.5 bar.Get Price

  • STATE OF CALIFORNIA, Governor Department of Industrial

    PRESSURE VESSEL UNIT . 1515 Clay St., Suite 1302 . Oakland CA 94612 blow down the boiler, address a low water condition or carryover, and can shut down the boiler) and proper maintenance of the boiler will take the water level to drop from the normal operating level to the lowest permissible water level. For most boilers, this time is Get Price

  • Monitoring of the water quality | Bosch steam boiler

    With a water hardness of 10° dH (medium hardness), up to 70g of limescale is transported per m 3 of water. If this value is extrapolated for a boiler with a steam output of 10 t/h operating continuously for 10 days, the results is nearly 500kg of limescale in the boiler.Get Price

  • Low Pressure Boiler - utopiamembrane.com

    Reduce the Scalable Ca, Mg, hardness in treated water Reduce the boiler blowdown which will save the fuel cost. Improve efficiency of the boiler with improvement in Heat Transfer rate. Reduce Boiler Chemical Consumption. No Manual Intervention is required for system Operation. Avoid effect of Leakage hardness from Primary Softner.Get Price

  • what is the hardness concentration of boiler water

    Hardness. The hardness of water is caused by calcium and magnesium ions which will vary greatly throughout the country depending on the source of the water. In boilers the hardness of the water can cause the formation of scale and sludge or mud. The hardness must be removed in the makeup water to the return system. Total hardness should not Get Price

  • Water for the Boiler - Spirax Sarco

    Hardness - Hard water does not foam. However, boiler water is deliberately softened to prevent scale formation, and this gives it a propensity to foam. Colloidal substances - Contamination of boiler water with a colloid in …Get Price

  • Water Handbook -Boiler Deposits: Occurrence And Control | SUEZ

    Deposition from low (less than 1.0 ppm) hardness boiler feedwater is eliminated with chelant programs and can be reduced by up to 95% by a good polymer/phosphate treatment program. Iron oxide is an increasingly significant contributor to boiler deposits because of the virtual elimination of hardness deposits in many systems and because the high Get Price

  • Low Pressure Boiler License Flashcards | Quizlet

    The evaporation of 34.5 pounds of water per hour from and at 212 F is defined as. one boiler horsepower. Boiler furnace explosions are likely to occur for all of the following reasons except. Low fuel pressure. All of the following boiler fittings …Get Price

Discount
7X24 Online