Through this webpage, choose online customer service communication, or message board. Leave your needs and get limited time discounts, up to 10% off, saving you a fortune. This discount has an indefinite period, and places are limited on a first-come, first-served basis.
We support various payment methods:
T/T payment
VISA
paypal
MasterCard
Alipay etc
Save time in your buying process.
The company's products have passed multiple national
certifications:
for example:
United States: ASME
EU: CE
Eastern Europe: EAC
Russia: GOST
Singapore: MOMO
etc
Buy products, buy with confidence, use with confidence
Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler
FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!
If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.
Reasons why the condensate- or boiler-feed - Heating Help
Capacity:1-20t/h
Rated thermal efficiency: 100-104%
Fixed working pressure: ≤1.6MPa
Applicable fuel:natural gas etc.
Capacity:0.7-14MW
Rated thermal efficiency:96-98%
Fixed working pressure:≤1.25MPa
Applicable fuel:Natural gas, light oil, etc.
Capacity:0.7-2.8Mw
Rated thermal efficiency: 97.2-106%
Fixed working pressure:0.1MPa
Applicable fuel:Natural gas, etc.
Capacity:2.8-7.0Mw
Rated thermal efficiency:≥105.5%
Fixed working pressure:-0.02MPa
Applicable fuel:Natural gas, etc.
Capacity:99Kw
Rated thermal efficiency:97.2-104.4%
Fixed working pressure:1.0MPa
Applicable fuel:Natural gas, etc.
Capacity:0.5-4.0 t/h
Rated thermal efficiency:98%
Fixed working pressure:≤1.25MPa
Applicable fuel:electric energy
Look at the near-boiler piping. If water is leaving the boiler with the steam, you'll never be able to heat the building. The near-boiler piping's job is to separate the steam from the water and put the water back into the boiler. Get the boiler manufacturer's specs for that near-boiler piping and compare it to what you see on the job.Get Price
Condensate is an excellent source of feed water as it is relatively pure (compared to most water supplies) being condensed water vapor. Boiler water cycles of concentration can be increased and blow down amounts can be reduced with its use. Improves energy efficiency. Reduces water treatment chemical cost. Reduces make-up water costs.Get Price
Reasons why the condensate- or boiler-feed pump is Get Price
Reasons why the return lines are clogged, and where to Get Price
With modern, wall-hung, light-weight gas boilers, water flow rate is particularly important. Check that the mains water is on. If it is, check your feed and expansion tank (if you have them, they're usually found in the loft). Float valve First, shut down your central heating boiler.Get Price
There are numerous technical reasons why the boiler has to have a somewhat elevated stack temperature. Don't have tunnel vision on that and miss the other things that can be done safely. Your not by any means the first to think of recovering heat from the flue, but the only ones who are successful in doing it are the appliance manufacturers and Get Price
Aug 30, 2016 · When it comes to boiler-feed pumps, the two important variables are the amount of water in the operating range of the boiler and the steam-to-condensate time lag across the system. The operating range is the vertical distance between the center of the gauge glass and the low-water cutoff point. It's not something manufacturers usually publish in their literature, …Get Price
This is done by converting water vapor condensation into heat; they're able to recover some of the lost heat from waste gases. The only difference between a condensing boiler and a non-condensing boiler is the amount of useable heat it produces; plus the fact they can achieve over 90% energy efficiency.Get Price
Jul 09, 2019 · Main article: Boiler keeps losing pressure: 7 possible reasons why. Blocked condensate pipe – one of the most common boiler problems in the winter. Instead of expelling hot combustion gases straight out into the atmosphere, condensing boilers draw so much heat out of them that the water vapour within them condenses back into a liquid.Get Price
A boiler may stop providing central heating or hot water for several reasons: The boiler has become disconnected from the power, gas or water supply. These connections can be switched off accidentally or during a power outage. If the boiler pressure becomes too high or too low the system turns off automatically, causing a lack of heat and hot waterGet Price
Four Reasons Why Boiler Water Treatment is Important There are four main reasons why water quality is so important. Impurities in water form scales. Water contains dissolved salts, which upon evaporation of water forms scales on the heat transfer surfaces.Get Price
Feb 09, 2022 · 2006. Q. I would like to add on his question in relation to our plant. we have a high pressure boiler but we minimize our blowdown in relation to silica and pressure. in two months time without blowdown, we have observed decreasing pH in the feed and boiler water even with 2-3 ppm phosphate. our treatment if ammonia and hydrazine at the feedwater and TSP for the …Get Price
Apr 17, 2017 · No reason in theory why your soakaway shouldn't go under your drive, and it is DIYable, but it does need to be accessed as part of the annual boiler service to top up the limestone chippings. You also need to consider how you might prevent your drive sinking into the pit - some sort of reinforcing structure would be required.Get Price
Dec 17, 2019 · The heat exchanger of your boiler is broken. The condensate trap and pipe come straight out of the heat exchanger, which means that if it cracks or pinholes, it will cause system or mains water to drain into the condensate pipe. What may lead to the condensate pipe leaking is if the hot water causes the pipe joints to fail somehow.Get Price
Sep 23, 2016 · Reasons why the condensate- or boiler-feed pump is misbehaving … Jun 25, 2014 … As steam traps fail, the returning condensate will get hotter. … to keep the water in the boiler from flowing backwards into the receiver tank.Get Price
Burks Falls, Ontario . Manufactured in Burk's Falls since 1961 and completely updated for 2016, the Thompson Model "A" Steamer is a completely self contained, simple to operate portable steam boiler system for municipal use, road maintenance,…Get Price
Steam or condensate wasted to grade elevates the need for additional make-up water. Make-up water requires heating with diverted boiler steam that could otherwise have been used for process heat. Diverted or lost steam/condensate can have the effect of lowering boiler steam temperature, which has a direct effect on the logarithmic mean Get Price
Manufacturer and supplier of Oilfield Steam Boiler. about Oilfield Steam Boiler We can manufacture subcritical boiler, supercritical boiler and overheated boiler with steam dryness.The unique matching water treatment equipment can …Get Price
Apr 30, 2011 · Too much water flows from the boiler with the steam. That loss of water calls the automatic feeder into action.When the condensate returns, the boiler floods. A good pH for a steam system ranges between 7 and 9. When the pH reaches 11,the water will foam. This is why old-timers added vinegar to the boilers.Get Price
Jan 01, 2000 · This system has a gravity return and the boiler's water line, in its present elevated state, is covering the wet returns that dip under doorways. If you're replacing that boiler, you're liable to wind up with steam in those wet returns if you lower the boiler to the floor, or if you add a condensate- or boiler-feed pump to the system.Get Price
Apr 23, 2017 · - Steam boiler running too hot: for example if the oil burner nozzle was changed to a higher gph rate the boiler may be over fired, causing steam to leave the boiler too rapidly for the condensate return rate - I see this as a different type of surge that causes the water feeder to send water into the boiler; then as the condensate later Get Price
Feb 20, 2021 · This is where combi boilers come in. Switching to a combi boiler will not only make your heating and hot water systems much more efficient, but it could save you money and make running a busy household much easier. Read on to discover 4 reasons why you should upgrade to …Get Price
May 20, 2015 · Here are 10 common reasons steam-heating boilers flood. 1. The water line surges, turning the automatic water feeder on and off. Surging begins when dirt and oil accumulate on the boiler water's surface. As the steam tries to break free, it lifts the water, creating the surge. You can see this in the gauge glass.Get Price
Reasons why steam boilers flood, and where to look for Get Price
Feb 20, 2021 · This is where combi boilers come in. Switching to a combi boiler will not only make your heating and hot water systems much more efficient, but it could save you money and make running a busy household much easier. Read on to discover 4 reasons why you should upgrade to …Get Price
Jan 09, 2013 · There are two main ways burner manufacturers have accomplished this without post-combustion control: steam injection and flue-gas recirculation (FGR). Steam injection—injecting steam into a flame—works because steam temperature is considerably lower than flame temperature—in the case of a boiler operating at 300 psig, 421°F vs. 2,400°F Get Price
Mar 29, 2020 · Reasons why steam boilers flood, and where to look for solutions. Dirty water, a too-high pH, overfiring and improper near- boiler piping can all cause the boiler's water line to surge up and down. If there's an automatic water feeder on the boiler, it will open and close each time the water line rocks.Get Price
Feb 07, 2019 · There are many reasons why a boiler will shut off automatically. In this article, we discuss the most common problems for boiler shutdowns and briefly explain how you can fix them. While we recommend calling a gas-safe registered engineer to handle repairs for you, there are some checks and quick-fixes that you can perform yourself.Get Price
A de-aerator can be used to heat feedwater by mixing it rigorously with hot condensate and flash steam. This process can vent off dissolved gases. The animation below describes the working of a de-aerator. Atmospheric boiler-feed tanks are normally operated at approximately 85-95 °C, which leaves an oxygen content of around 2mg/liter (ppm).Get Price
Feb 10, 2022 · Why Your Boiler At Home Keeps Switching Off? Here Are The Potential Reasons. Posted on Liming by culprit44 in Construction // 0 Comments Liming by culprit44 in Construction // 0 CommentsGet Price