Through this webpage, choose online customer service communication, or message board. Leave your needs and get limited time discounts, up to 10% off, saving you a fortune. This discount has an indefinite period, and places are limited on a first-come, first-served basis.
We support various payment methods:
T/T payment
VISA
paypal
MasterCard
Alipay etc
Save time in your buying process.
The company's products have passed multiple national
certifications:
for example:
United States: ASME
EU: CE
Eastern Europe: EAC
Russia: GOST
Singapore: MOMO
etc
Buy products, buy with confidence, use with confidence
Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler
FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!
If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.
Procedure for Blowdown of Boiler Guage Glass
Capacity:1-20t/h
Rated thermal efficiency: 100-104%
Fixed working pressure: ≤1.6MPa
Applicable fuel:natural gas etc.
Capacity:0.7-14MW
Rated thermal efficiency:96-98%
Fixed working pressure:≤1.25MPa
Applicable fuel:Natural gas, light oil, etc.
Capacity:0.7-2.8Mw
Rated thermal efficiency: 97.2-106%
Fixed working pressure:0.1MPa
Applicable fuel:Natural gas, etc.
Capacity:2.8-7.0Mw
Rated thermal efficiency:≥105.5%
Fixed working pressure:-0.02MPa
Applicable fuel:Natural gas, etc.
Capacity:99Kw
Rated thermal efficiency:97.2-104.4%
Fixed working pressure:1.0MPa
Applicable fuel:Natural gas, etc.
Capacity:0.5-4.0 t/h
Rated thermal efficiency:98%
Fixed working pressure:≤1.25MPa
Applicable fuel:electric energy
Sep 16, 2021 · Gauge glass blow down procedure . Gauge glass should be blown before lighting up of boiler, after stopping the boiler and regularly if the level in gauge glass is suspected to be wrong. Cleaning the water side of gauge glass. Close the valve S and W as shown in the figure.Get Price
Mar 30, 2015 · Chapter 8 — Boiler Operation Procedures When blowing down the gauge glass, water should enter the gauge glass quickly when the gauge glass blowdown valve is closed. 4. Chapter 8 — Boiler Operation Procedures During a bottom blowdown, the boiler should be under light load and the water level should be at the NOWL. 5.Get Price
Gauge Glass Blow-Down Procedure. When operating a boiler gauge glass it is necessary to follow a defined procedure to reduce the probability of thermal shocking and consequent rupturing of the glass plates. The defined procedure is known as a boiler gauge glass blow down procedure and is necessary learning for anyone involved with steam generators.Get Price
Klinger reflex level gauges are used to indicate the level of liquids in boilers and vessels. Reflex glass (3), is installed between of the centre piece (1) and the cover plate (2). In the following procedure is recommended to bring the gauge back into …Get Price
May 29, 2021 · Boiler gauge glass blowdown It is possible for the small water or steam passage to block with scale or dirt and the gauge will give an incorrect reading. To check that passages are clear a "blowing through" procedure should be followed.Get Price
Nov 28, 2020 · meaning of the gauge glass blowdown|why blowdown required by gauge glass|what is cross blowdown procedure|how normal blow down is carried out in boiler|Get Price
Boiler Gauge Glass Blow Down Procedure and Maintenances March 10, 2015 April 16, 2016 Mark Eriscson 1 Comment Boiler Survey, Marine Boiler, Marine Engineering Practice. Boiler gauge glass needs to be blow down, regularly, to make sure that it is showing the correct reading and there is no blockage in the line of water and steam.Get Price
Oct 12, 2001 · In Reply to: Re: Blowdown + gauge glass posted by sruli on October 11, 2001 at 10:59:54: Straight below the glass tube there should be a little petcock, or valve that squirts onto the floor. When up to pressure, you close both of the bigger glass shut-offs, open the petcock or remove the pipe plug if that's what is there.Get Price
Section I Requirements for Gage Glass Placement on Fire Tube Type Boilers. 1- Lower side steam conn. 2- Upper side water conn. 3- Level A . 4- Low vision. 5- Drum. 6- High vision. 7- Steam conn. Level "A" = Lowest Permissible Water Level, at which there will be no danger of overheating the boiler. Lowest vision = 1 in. on boilers < 16 Get Price
Procedures commonly completed during a shift include water column and gauge glass blowdown, bottom blowdown, low water fuel cutoff testing, and flame scanner testing. Boiler Log The boiler room log lists boiler operation data that can be used to increase boiler safety and efficiency as well as identifying a potential malfunction.Get Price
Oct 08, 2019 · Feed water pump must be in auto. Procedure. Open ship side valve. Open boiler blowdown valve gently. Control the blowdown rate using intermediate valve. (while blowdown keep an eye on gauge glass, in my ship we use blowdown for 120 seconds every alternate day) (however the blowdown rate depends on boiler water test report) Once blowdown is done Get Price
Jun 29, 2020 · In this video, we have nicely explained you the Boiler Gauge Glass Blow Through Procedure and hence after watching this video you will get a complete idea ofGet Price
installed close to the gauge glass to minimise level differences between the chamber and gauge glass. The chamber band mark indicates the lowest adjustment position of low level alarm and it is our recommendation that the positioning of the boiler control chambers relative to the water level gauge glasses and the N.W.L.Get Price
Gauge glass is a type of level sensor, a transparent tube through which the operator of a tank or boiler can observe the level of liquid contained within. [pool1] 76 items. [pool1] 76 items. Reset.Get Price
Dec 24, 2020 · Procedure for Boiler Gauge glass line up & Flushing Boiler Gauge glass: is a transparent glass of shape tubular, flat or square blocks fitted to the boiler steam drum to facilitate a visual indication of the water level of a steam drum. These types of glasses are manufactured by borosilicate glass which is robust, temperature & chemical resistant.Get Price
KLINGER level gauges, originally invented by Richard Klinger more than 110 years ago, still serve to reliably indicate the liquid level in boilers and vessels today. An efficient process operation demands high-performance measurement installations. KLINGER fluid monitoring products stand out from the competition as a result of their excellent Get Price
an automatic blowdown valve, the Blowdown Tank must be filled with cold water to the center of the gauge glass level. Open the cold water supply valve until the level is about half way up the blowdown tank gauge glass. The water in the tank is intended to mix with the hot boiler water and temper it before it goes down the drain. After aGet Price
How to Perform a Boiler Blowdown | DoItYourself.comGet Price
In most plants, the suggested operating procedure is to blow down the water column and gauge glass ___. F T/F Softened water is used in a boiler to prevent pitting of the boiler metal.Get Price
If the glass is replaced while the boiler is in service, open the blowdown valve and slowly bring the glass to operating temperature by cracking the gauge valves slightly. After the glass is warmed up, close the blowdown valve and open the gauge valves completely. Check the try cocks and gauge cocks for freedom of operation and clean them as Get Price
Jun 15, 2021 · Boiler blowdown is the act of removing water from a boiler in operation in an effort to remove sediment, chemical concentrations and solids. This helps to prevent carryover, corrosion, and scaling. In short, boiler blowdown ensures high quality steam and a …Get Price
Boiler Gauge Glass Blow Down Procedure and Maintenances March 10, 2015 April 16, 2016 Mark Eriscson 1 Comment Boiler Survey, Marine Boiler, Marine Engineering Practice. Boiler gauge glass needs to be blow down, regularly, to make sure that it is showing the correct reading and there is no blockage in the line of water and steam.Get Price
PROCEDURE 1. Clear the boiler for firing by taking the standard precautions. 2. Inspect all internal waterside surfaces, including tubes, and remove any debris. It may be necessary to use a high pressure hose to flush out inaccessible areas. 3. Replace the regular gauge glass with temporary gauge glass that can be discarded after the cleaning. 4.Get Price
Your guide to safer boiler operation. Steam boiler. 1. Safety valve 2. Low-water cutoff 3. Water column blow-down valve 4. Pressuretrols (one is high-limit safety) 5. Steam pressure-gauge 6. Water column clean-out (cross tee) 7. Bottom blow-off and drain valve 8. Low-water cutoff/blow-off valve Note: Second low-water-cutoff not shown in diagramGet Price
In regards to Boiler Gauge Glass Blowdown, Why is the standard practice to open the water cock first? The standard procedure for gauge glass blowdown can easily be found on google search, however the explanation as to why, after blowing down, the water cock is opened first to fill the gauge followed by steam is never explained.Get Price
d. look around for leaks, check on gauge glass accuracy, check blowdown valves if they are close, open vent valve to release pressure and then cool down for inspection b A digital control system that monitors the startup sequence and operation of a boilerGet Price
Boiler Gauge Glass Blow Down Procedure and Maintenances March 10, 2015 April 16, 2016 Mark Eriscson 1 Comment Boiler Survey, Marine Boiler, Marine Engineering Practice. Boiler gauge glass needs to be blow down, regularly, to make sure that it is showing the correct reading and there is no blockage in the line of water and steam.Get Price
Procedure for Blowdown of Boiler Guage Glass. by Manoj. 5. > Close water cock and steam cock of gauge glass and open the drain. > Open the steam cock a strong jet of steam should be seen from the drain after that close the steam cock. > Open the water cock a strong jet of water should be seen from the drain after that close the water cock and drain.Get Price
How to Clean a Boiler Glass Gauge. Close top and bottom gauge valves, but open the drain valve beneath the column. Open the top gauge valve just a fraction, so that steam pressure blows all of the water out of the drain line, leaving only steam remaining in …Get Price
What is the purpose of a boiler blowdown tank? - Frank Get Price