Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler
FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!
If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.
JINASENA - Water Purifiers IN SRI LANKA BOILER WATER
Capacity:1-20t/h
Rated thermal efficiency: 100-104%
Fixed working pressure: ≤1.6MPa
Applicable fuel:natural gas etc.
Capacity:0.7-14MW
Rated thermal efficiency:96-98%
Fixed working pressure:≤1.25MPa
Applicable fuel:Natural gas, light oil, etc.
Capacity:0.7-2.8Mw
Rated thermal efficiency: 97.2-106%
Fixed working pressure:0.1MPa
Applicable fuel:Natural gas, etc.
Capacity:2.8-7.0Mw
Rated thermal efficiency:≥105.5%
Fixed working pressure:-0.02MPa
Applicable fuel:Natural gas, etc.
Capacity:99Kw
Rated thermal efficiency:97.2-104.4%
Fixed working pressure:1.0MPa
Applicable fuel:Natural gas, etc.
Capacity:0.5-4.0 t/h
Rated thermal efficiency:98%
Fixed working pressure:≤1.25MPa
Applicable fuel:electric energy
May 03, 2018 · Boiler Water Treatment is necessary to Producing quality steam on demand depends on properly managed water treatment to control steam purity, deposits and corrosion. There are two main types of boiler feed water treatment Internal boiler Water Treatment method and external boiler water treatment. A boiler is the sump of the boiler system. It ultimately …Get Price
Boiler water testing is an integral part of the routine boiler tests in many industries like Textile, Rubber, Pulp and Paper, Food, Distilleries, Dyers and Paint. A regular boiler water test assures higher efficiency and reduced maintenance of boilers. It is quite essential to maintain correct water conditions by careful monitoring of boiler Get Price
A range of products including: electronic burner control systems, O2 trim, variable speed drives and boiler water control will be on show at the stand along with advice on burner and boiler servicing, training and the use of data loggers to prove …Get Price
Oct 26, 2018 · Steam Boiler Water Feeder Valve Q&A #2 Recent FAQs on how to diagnose & fix a water feeder valve . POST a QUESTION or COMMENT about how and when to use and maintain the water feed valve on steam boilers; diagnosis of causes of steam boiler over-filling or water feed valves that don't shut off.Get Price
Water used in boiler feed should be as pure as possible. Boiler water contacts boiler heat exchangers, pumps, valves and associated piping. Water impurities like suspended or dissolved solids or dissolved gases produce negative effects within the system. Water treatment specialists, in order to understand the process better, use grab sample testing methods or …Get Price
Feb 24, 2016 · A boiler water sample has an un-neutralized conductivity of 5 000 µS / cm at 25°C. What is the conductivity of the boiler water at 10 bar g?At 10 bar g, saturation temperature = 184 °C (from steam tables) σT = 5,000 [1+0.02(184-25)]Get Price
Boiler Water Quality Boiler Chemicals are used to ensure proper Boiler Water Quality in boilers. The below table is the Total Dissolved Solids or TDS, Alkalinity, and Hardness versus Boiler Pressure. First, knowing the water source is important, whether it is from ponds, rivers, ground wells, or city water.Get Price
May 04, 2016 · Boiler water chlorides limits are set on the ideas that: The boiler should get good fuel efficiency, and, Based on both makeup and treatment dissolved solids, the total boiler water dissolved solids should not go so high that carryover, scaling and corrosion are a …Get Price
A well-balanced internal and external boiler water treatment program addresses all of the potential problems associated with boilers, including: 1) The control or removal of calcium and magnesium hardness through external (mechanical) pretreatment or …Get Price
Jun 09, 2017 · hydrazine test: – this test is carried out to find out reserve hydrazine in boiler water which is an oxygen scavenger. reserve should be between 0.1-1 ppm. test procedure:-a)take 250 ml of cooler boiler water sample, 15 ml of n/2 hcl and 2 nesslers cylinders. b) in 1st cylinder add 25 ml sample and then add 4-dimethylaminobenzaldehyde.Get Price
Our combi models can deliver whole house heating and simultaneous domestic hot water. The i060CN provides an input rating of 60K BTU. Fueled with either Natural Gas or Propane this Rinnai condensing gas boiler has obtained 1 of the highest AFUEs …Get Price
Sep 03, 2020 · An example of this combining of ions is the action between Calcium and Carbonate. The chemical compound which forms is Calcium Carbonate. Other impurities which will affect the boiler water treatment control include Copper, Iron Oxides, oil and dissolved gases.Get Price
Apr 14, 2021 · Boiler water treatment and chemistry are two things you need to be aware of. Learn more about these two critical aspects of running your facility.If you use boilers at your facility, boiler water treatment and chemistry are two things you need to be aware of. Just like any other area of your facility's operation, you need to ensure that your boilers are working within the …Get Price
Our Boiler Water commercial water heaters generate domestic hot water from boiler water maximizing efficiency with return water temperature as low as 80°F. They feature maximum water pressure of 150+ psi, recoveries from 10-7600 gph and storage capacities ranging from 150-4500 gallons. Available in U-tube, single or double walls, instantaneous Get Price
Boiler water chemical treatment coupled with 3D TRASAR technology provides comprehensive boiler water treatment solution mitigating scale and corrosion of the boiler system. Remote monitoring by the System Assurance Center further allows you to focus on profitability of your operations. Connect today with our sales engineers and improve Get Price
boiler water treatment may be added (fed) to the water in the steam drum. A process of either continuous or intermittent surface blowdown is used to maintain the TDS of the boiler water and achieve the optimal operating conditions in the boiler. In some boiler systems, the blowdown water will be discharged to a flash tank, where a lowerGet Price
This VGB-Standard supports the operator of water-steam cycles in power plants and related branches in selecting and judging suitable water regimes with respect to a safe and economically sound operation of the power plant for a long period of time.Get Price
Boiler water returned to feed tank May include economiser and superheater. Steam Generator - Coil. Basic Boiler Principles. HOT WELL DEAERATOR EXTERNAL TREATMENT MAKE UP RETURNED CONDENSATE WATER AND HEAT FEEDWATER WATER AND SOLIDS SATURATED STEAM EVAPORATED WATER Continuous blowdown to remove dissolvedGet Price
May 26, 2019 · Boiler Water Quality Requirements and Associated Steam Quality for Industrial and Commercial and Institutional Boilers by ABMA (American Boiler Manufacturers Association). The purpose of this manual is to acquaint engineers, purchasers, and operators of industrial, commercial and institutional (ICI) boilers with ABMA's judgment as to the relationship between …Get Price
PARAMETERS FOR BOILER WATER : PARAMETERS pH TH P AL. M AL. T.D.S Amine Sio2. Chloride Iron ( Fe ) STANDARD 9.5 10.2 NIL 5 8ppm 10 …Get Price
Boiler Water Tests from $19.99. In stock and ready to ship today! View pricing and order online. Visa, Mastercard, Paypal, and Credit Applications accepted.Get Price
Under boiler water conditions, bicarbonate decomposes first to carbonate and then to carbon dioxide . The carbon dioxide leaves the boiler with the steam and forms carbonic acid in the condensate system. The sodium that was attached to the bicarbonate reacts to form alkalinity. In all cases it is the boiler water hydroxyl alkalinity, as measured byGet Price
Boiler Water Testing Kits for Steam and Hot Water Boilers. Order online and save today.Delivery. Order online or call 800-768-5810.Get Price
Four boiler water treatment programs were evaluated for their ability to transport metal ions through 600 psi (41 MPa) waste heat recovery steam generators. Phosphate/sulfite alone failed to transport Ca, Mg, or Fe metal ions through the boiler. The addition of a polymer to the phosphate/sulfite transported Mg through the boiler and aided in Get Price
Sep 02, 2019 · When you hear the term boiler water, this refers to any water that's situated in a boiler or the pumps and piping surrounding the boiler for the main purpose of being evaporated into steam. Boiler water is used in many different industries for such applications as heating, sterilization, and humidification. These industries include metalworking, electrical, […]Get Price
May 02, 2000 · boiler water chloride level should be monitored to ensure the blow down rate is correct. If the chloride level is higher than the recommended maximum, more blow down is needed. If it is low, excess blow down is occurring, resulting in wasted chemicals, water, and heat energy. In some cases the chloride level never approaches the recommendedGet Price
2/18/2014 3 Cheat Sheet - Reactions • Bicarbonate Break: Na 2 HCO 3 + HEAT Na 2 CO 3 + CO 2 + H 2 O • Developed Alkalinity: Na 2 CO 3 + HEAT + 2H 2 O 2NaOH + CO 2 + H 2 O • Brining Reactions: CaCl + Boiler Water CaSO 4 + CaSiO 3 • Phosphate Reactions: …Get Price
Establishing a boiler water treatment plan will provide you with real-time feedback of your boiler system so you can get ahead of any issues that might occur as a result of poor water quality. We broke down the boiler water treatment process into three simple steps that you can incorporate into your preventative maintenance practices. 1.Get Price
Feb 24, 2016 · A boiler water sample has an un-neutralized conductivity of 5 000 µS / cm at 25°C. What is the conductivity of the boiler water at 10 bar g?At 10 bar g, saturation temperature = 184 °C (from steam tables) σT = 5,000 [1+0.02(184-25)]Get Price
Neutralizing amines – those which lower pH – are used in boiler water treatment to control corrosion in condensate return lines. This is one of the most asked about and often misunderstood applications for pH control in the chemical feed. Neutralizing amines are used in boiler water treatment to control condensate return line corrosion.Get Price