Press the left button, drag the mouse, rotate the cube, see more information

Limit Discounts

Through this webpage, choose online customer service communication, or message board. Leave your needs and get limited time discounts, up to 10% off, saving you a fortune. This discount has an indefinite period, and places are limited on a first-come, first-served basis.

Payment Method

We support various payment methods:
T/T payment
VISA
paypal
MasterCard
Alipay etc
Save time in your buying process.

Certified Product

The company's products have passed multiple national
certifications:
for example:
United States: ASME
EU: CE
Eastern Europe: EAC
Russia: GOST
Singapore: MOMO
etc
Buy products, buy with confidence, use with confidence

Product Type

Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler

About Us

FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!

Contact Us

If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.

Opentherm Installation - Ideal Logic C3Combi Boiler

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :Opentherm Installation - Ideal Logic C3Combi Boiler
  • Supply Capacity : 10 units/month :Opentherm Installation - Ideal Logic C3Combi Boiler
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • INSTALLATION & SERVICING - Ideal Heating

    Installation and Servicing 3 LOGIC ESP1 COMBINATION BOILER Ideal Boilers ERP DATA SYMBOL UNITS MODEL 24 30 35 Condensing boiler Yes Seasonal Space heating efficiency class A Rated heat output kW 24 Seasonal space heating energy efficiency ƞ s % 94* Annual energy consumption Q HE GJ 75 Sound power level, indoors L WA dB 48 46 44Get Price

  • Nest thermostat logic combi esp1 35 wiring | Screwfix

    Nov 29, 2020 · It's a combi boiler made by ideal logic it's an esp1 35 Robert Johnston, Jul 7, 2019 #3. and OT1 and OT2 are not used unless an opentherm boiler it seems your boiler is OpenTherm so they are likely the only wires used, if not using OpenTherm I have never worked out what FP is used for, you can forget it, so only C and NO are connected with Get Price

  • Ideal Logic Max Boiler Installation / Open Therm / Nest

    Opentherm Boilers & Controls | Compatibility GuideGet Price

  • Nest 3rd Gen & Ideal Logic ESP1 35 Opentherm | Screwfix

    Dec 12, 2019 · Steven Atherton New Member. I have a third gen nest thermostat connected to my Ideal Logic ESP1 35 combi boiler. I'd like to connect it to the Opentherm connection. I thought I had it wired up properly, but when I turn the boiler back on, the boilers display just reads "00". Connect it back to the on/off connection and it works fine.Get Price

  • Benefits of OpenTherm Connectivity | Boilers | Ideal Heating

    Oct 30, 2019 · OpenTherm protocol is controlled by the OpenTherm Association, of which Ideal Boilers is a member. Ideal Logic boilers have OpenTherm wiring connections meaning operation is optimised when an OpenTherm room thermostat or programmable room thermostat (PRT) is …Get Price

  • Ideal Logic C30 Combi Boiler Full Review & Guide | Boiler

    Jan 24, 2022 · Ideal Logic C30 combi boiler – Final overview. This solution is the Ideal combi boiler for small homes and flats that have few bathrooms and a small central heating system. Without any hot water tanks or much additional external apparatus, the Ideal Logic C30 combi boiler is an excellent choice for homes with limited space.Get Price

  • Installation Servicing OpenTherm Harness Kit - Ideal Heating

    If 230V is connected then the boiler electronics will be destroyed. Wiring the OpenTherm Harness Kit to the boiler 1. Isolate the electricity supply to the boiler. 2. Remove the boiler front panel (refer to boiler installation instructions). 3. Hinge down the control box. 4. Connect the wires from the OpenTherm device to theGet Price

  • Logic Max Combi Boiler | ErP | Boiler Installers | Ideal

    Available in three different outputs of 24kW, 30kW & 35kW, the Logic Max range of combi boilers has been designed to ensure a quick and hassle free installation with plenty of room inside to make it easily accessible. * Typical combined primary and secondary length. See installation instructions for more details. C24. C30.Get Price

  • Ideal logic Combi, weather management & OpenTherm question

    Sep 03, 2019 · Weather comp reduces the flow temperature, and consequently the return temperature, as the outside temperature increases. This results in less fuel used and an increase in the percentage of water vapour condensed. Meaning the boiler is more efficient. If both Opentherm and weather comp are installed the OT thermostat uses the outside Get Price

  • Wired Thermostat and Ideal Logic Combi ESP1 35 / New Build

    The set up in the new home I am moving into is that we have an Ideal Logic Combi ESP1 35 boiler which is linked via relay to an ESI Thermostat/programmer in the hallway. I had initially purchased the stat thinking that I could simply swap and gain the benefits of having an opentherm heating system but after having spent along time reading I don Get Price

  • Nest -heat link control wiring to Ideal Logic plus 30 boiler

    Sep 23, 2019 · Joined: 28 May 2016. Posts: 29. Location: Nottingham,UK. Hi all i'm just in the process of completing my Nest V3 (heat link) which is wired to my Ideal logic combi boiler. I've done the Nest to the heat link. I've also done the 230V from the combi to the Heat link using a 5 core heat resisting cable. Just the control to do which i needed advice Get Price

  • Nest Install Logic Combi Boiler | DIYnot Forums

    Sep 03, 2019 · Hoping someone can offer some advice on a Nest install for a Logic + Combi boiler. I'm not against getting someone out to install if necessary but wanted to check if I could do it myself if it's fairly straightforward. I've got a stand for the Nest so no need to cable it back to the heat link. It's replacing a Siemens Wireless stat, which is Get Price

  • Ideal logic H12 and OpenTherm - DIYnot Forums

    Oct 27, 2019 · According to the Installation Instructions for the Logic Heat H 12 15 18 24 30, it does have terminals marked Opentherm, but no mention of them in the text. The diagrams below it in the manual just show a standard 'S Plan' and 'Y Plan' which because the microswitch in the motorised valves that controls the boiler is just a simple on / off Get Price

  • Trying to wire smart thermostat to ideal logic combi

    Sep 19, 2020 · I own an Ideal Logic Combi 30 boiler and am trying to wire the new thermostat to said boiler. I so far have taken a twin and earth to the back of the thermostat from the spur which feeds the boiler and have wired the dry contact with a separate twin and earth to go direct to the boiler, to, hopefully, be connected to the terminals marked "room Get Price

  • Ideal 175603 Harness Opentherm - Pre Prefix Abk - Logic

    Buy your Ideal 175603 - Logic Combi E 35 Harness Opentherm - Pre Prefix Abk today, with a fast UK delivery.. The ideal Logic Combi E 35 wiring harness assy these are a number of wires bundled or can be single together, every cable is in charge of the electrical signals and energy power transferred to componenets in the boiler., Ideal Wiring Get Price

  • Getting started — tado° Community

    Opentherm Installation - Ideal Logic C30 Combi Boiler Answered theronster 862 views 7 comments 0 points Most recent by tadouser1000 April …Get Price

  • Ideal Logic C30 NG Combi Boiler - MacBlair

    Available in outputs of 24, 30 and 35kW, the Logic C Combi is designed to ensure a quick and hassle-free installation thanks to concealed connections, built-in automatic bypass and an integral filling loop. A translucent condensate siphon also allows any debris to be spotted quickly and efficiently. Features & Benefits. Output 30.3kW; 12.4 I/m Get Price

  • Hive and Ideal Logic Combi 30 | DIYnot Forums

    Mar 14, 2021 · Hi, new here and i apologise if this has been asked a thousand times. Im looking to fit Hive to my current boiler which is a ideal logic combi 30 which is controlled remotely (no wires) by an ideal PRT3 programmer in the living room.Get Price

  • Ideal Logic Code Combi 23 33 38 Installation Servicing

    Jun 15, 2019 · Boiler Manuals. Ideal Logic Code Combi 23 33 38 Installation Servicing Instructions Manual. GC Number. Model. Fuel. 47-348-74. …Get Price

  • Opentherm Boilers & Controls | Compatibility Guide

    Benefits of OpenTherm Connectivity | Boilers | Ideal HeatingGet Price

  • How do I wire a Nest Heat Link to Ideal Logic+ 24 | DIYnot

    Sep 03, 2019 · I am just in the process of putting my Nest V3 (heat link) to my Ideal logic+ Combi 24 [see link 1 for the boiler manual]. The boiler already has a RF Mechanical Thermostat plugged in, which I have unplugged from the boiler [see Pic 1 below]. I have wired the Nest as seen in Pic 2 below. I have left the link (red wire) in the boiler as-is Get Price

  • Installing 2 nest Thermostats on combi Boiler | Screwfix

    Feb 01, 2022 · My boiler is an Ideal Logic ES38 and it's controlled by 2 Honeywell CM707 thermostats. One for upstairs and one down. I've watched loads of videos and read tons and seems pretty straightforward to install for one stat with one heatlink but how do I do it for 2.Get Price

  • OpenTherm Boilers and Controls - MyBoiler.com

    Jan 05, 2017 · The Ideal Combi pre 2016 (like mine) supports OpenTherm with a harness kit, but not OpenTherm SmartPower, so you will need either a powered thermostat or a gateway. The newer boilers support SmartPower and work with the …Get Price

  • Hive Installation into Ideal Logic 30 | Screwfix Community

    Mar 14, 2021 · Hive Installation into Ideal Logic 30. Discussion in ' Electricians' Talk ' started by Gooner23, Mar 14, 2021 . Hi, new here and i apologise if this has been asked a thousand times. Im looking to fit Hive to my current boiler which is a ideal logic combi 30 which is controlled remotely (no wires) by an ideal PRT3 programmer in the living room.Get Price

  • Gas combi boiler step by step installation video (Ideal

    Mar 06, 2021 · #boiler #logic #idealThis is a step-by-step video of installation of an Ideal Logic Max C30 gas combination boiler. I take you through removal of existing boGet Price

  • Ideal Logic Plus Combi C24 C30 C35 Boiler Data Sheet

    EASY TO INSTALL AND SERVICE - Low boiler lift weight from 29.2kg - Compact cupboard fit OpenTherm controls - LPG conversion kit available for 30 kW boilers LOGIC+ COMBI 2.5 from the case Ideal Logic Plus Combi C24 C30 C35 Boiler Data Sheet Created DateGet Price

  • Ideal Logic C30 NG Combi Boiler - MacBlair

    Available in outputs of 24, 30 and 35kW, the Logic C Combi is designed to ensure a quick and hassle-free installation thanks to concealed connections, built-in automatic bypass and an integral filling loop. A translucent condensate siphon also allows any debris to be spotted quickly and efficiently. Features & Benefits. Output 30.3kW; 12.4 I/m Get Price

  • Nest Learning 3rd Generation UK Installation with Ideal

    How to install Nest Learning 3rd Gen thermostat on an Ideal Independent C24 Combi Boiler in UK. In this video I have shown how to run wires from boiler's theGet Price

  • Logic Combi Boiler ESP1 35 with Nest Learning Thermostat

    Dec 04, 2020 · Add installation instructions behind name of boiler and google and you get this set of instructions if I have the correct instructions looking at page 33 it seems likely you will need to replace the link fitted when the ESI 5 was fitted, and then connect up the 2 x 3 core cables for new thermostat, can't really use one cable as the connections are opposite sides of boiler for …Get Price

  • Ideal Logic Combi ES24 ES30 ES35 Installation Servicing

    Sep 06, 2019 · Ideal Logic Combi ES24 ES30 ES35 Installation Servicing Instructions Manual. September 6, 2019. Boiler Manuals. Ideal Logic Combi ES24 ES30 ES35 Installation Servicing Instructions Manual. GC Number. Model. Fuel. 47-349-01. Ideal Logic Combi ES24.Get Price

Discount
7X24 Online